Applied Biosystems 7500 Fast Real-Time PCR System + Computer & Software (9033)R

$ 15312

Availability: 100 in stock
  • Item must be returned within: 30 Days
  • Refund will be given as: Money Back
  • MPN: 7500 4345241
  • Condition: In good cosmetic condition. Powers on, computer responds well to input. The machine passes all function test. Calibrations is needed and all calibration kits are available from Thermo Fishers Online Website. See pictures for more detail.
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • Return shipping will be paid by: Seller
  • Brand: Applied Biosystems

    Description

    Applied Biosystems 7500 Fast Real-Time PCR System + Computer & Software (9033)R In good cosmetic condition. Powers on, computer responds well to input. The machine passes all function test. See pictures for more detail. Manufacturer: Applied Biosystems Model: 7500 Fast Real-Time PCR System | 4345241 Mfg: March 2006 Includes: AB 7500 Real-Time PCR System 7500 Software Installed Computer (OS: XP) w/ Keyboard and Mouse All necessary Cables Specifications: (These specifications were taken from an online user manual and may not be accurate to this product.) Dye: TAMRA, Cy3, FAM, SYBR Green, Texas Red, JOE, ROX, Cy5, NED, VIC Capacity: 12 x 8-tube strips, 1 x 96-well plate (Fast) Format: 96-well plate, 8-well strips Optics: CCD Camera, Halogen light source, Five excitation and five emission filters Passive Reference Dye: ROX (Separate Tube), Other Passive Reference Dye, ROX (Pre-mixed) Peak Block Ramp Rate: 5.5°C⁄sec Precision: Distinguish between 5,000–10,000 genome equivalents (two-fold copy number difference) with 99.7% confidence Reaction Speed: Fast, Standard Reaction Volume Range: 10-30 µl Run Time: 36 min (Fast), <2 hrs (Standard) Sample Ramp Rate: Fast mode: ± 3.5°C⁄sec Standard mode: ± 1.6°C⁄sec Temperature Accuracy: ±0.5°C Temperature Range (Metric): 4.0-99.9 °C Temperature Uniformity: ±1°C Thermal Cycling System: Peltier-Based System Throughput: 4 to 5 96-well plates per day For Use With (Equipment): 7500 Fast System Max. Heating Rate (Thermal Block): 5.5°C Dynamic Range: 9 logs of linear dynamic range Sensitivity: Down to 1 copy of human RNAse P gene Dimensions: Actual Dimensions: 13.39 x 17.72 x 19.29" Actual Weight: 75 lbs
    Applied Biosystems 7500 Fast Real-Time PCR System + Computer & Software (9033)R
    In good cosmetic condition. Powers on, computer responds well to input. The machine passes all function test. Calibrations are needed and all calibration kits are available from Thermo Fishers Online Website. See pictures for more detail.
    Manufacturer: Applied Biosystems
    Model: 7500 Fast Real-Time PCR System | 4345241
    Mfg: March 2006
    Lamp Hours Usage: 1473
    Includes:
    AB 7500 Fast Real-Time PCR System
    7500 Software (Installed) Ver. 2.0.1
    Computer (OS: XP) w/ Monitor, Keyboard, and Mouse
    All necessary Cables
    Extra Bulb Part #: 4443978
    Specifications: (These specifications were taken from an online user manual and may not be accurate to this product.)
    Dye: TAMRA, Cy3, FAM, SYBR Green, Texas Red, JOE, ROX, Cy5, NED, VIC
    Capacity: 12 x 8-tube strips, 1 x 96-well plate (Fast)
    Format: 96-well plate, 8-well strips
    Optics: CCD Camera, Halogen light source, Five excitation and five emission filters
    Passive Reference Dye: ROX (Separate Tube), Other Passive Reference Dye, ROX (Pre-mixed)
    Peak Block Ramp Rate: 5.5°C⁄sec
    Precision: Distinguish between 5,000–10,000 genome equivalents (two-fold copy number difference) with 99.7% confidence
    Reaction Speed: Fast, Standard
    Reaction Volume Range: 10-30 µl
    Run Time: 36 min (Fast), <2 hrs (Standard)
    Sample Ramp Rate:
    Fast mode: ± 3.5°C⁄sec
    Standard mode: ± 1.6°C⁄sec
    Temperature Accuracy: ±0.5°C
    Temperature Range (Metric): 4.0-99.9 °C
    Temperature Uniformity: ±1°C
    Thermal Cycling System: Peltier-Based System
    Throughput: 4 to 5 96-well plates per day
    For Use With (Equipment): 7500 Fast System
    Max. Heating Rate (Thermal Block): 5.5°C
    Dynamic Range: 9 logs of linear dynamic range
    Sensitivity: Down to 1 copy of human RNAse P gene
    Dimensions:
    Actual Dimensions: 13.39 x 17.72 x 1
    9.29
    "
    Shipping Dimensions: 24x27x45"
    Shipping Weight: 180 lbs
    Sold as is with 30 day Right of Return, only pictured items included
    Easy return/refund for any reason
    Anacapa Equipment
    RETURNS
    Anacapa Equipment Brokers, Inc. (“Seller”) strives to offer excellent customer service.   You may return any equipment purchased from us for any reason within thirty (30) days after your receipt of the equipment for a full refund of the purchase price, provided that returned items are received in the same condition as sent.  We DO NOT ship internationally.  If you are using a freight forwarder then returns are VOID.
    SHIPPING
    All equipment purchased is shipped within one (1) business day (subject to freight availability) after receipt of payment and is shipped FOB place of shipment.  We only charge actual shipping cost.  If eBay overcharges for shipping, we issue an immediate refund for the difference. If you are undercharged, we will absorb the cost.
    We DO NOT ship internationally.  IF you are using a freight forwarder then returns are VOID.
    LIMITED WARRANTY
    Buyer acknowledges that the equipment is being sold “as is" and without any warranty of merchantability or fitness for a particular use.  The entire risk as to the quality and performance of the equipment is with the Buyer.  Should the equipment prove defective following its purchase the Buyer and not the Seller, manufacturer, distributor, or retailer assumes the entire cost of all necessary servicing or repair.  Buyer may inspect the equipment prior to purchase and placement of the order.  Failure to inspect prior to placement of an order is deemed a waiver of Buyer’s right to inspect.  Buyer is responsible for determining the suitability of the equipment for its application.  Seller assumes no liability for the use or misuse of any equipment purchased by Buyer. It is assumed that the equipment will be installed and operated by qualified personnel. The Buyer agrees that the Seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment purchased.
    The Buyer, by purchasing this equipment, indicates its acknowledgment of, and agreement, to the terms of this limited warranty
    .
    INDEMNITY
    Buyer shall be solely liable for, and shall defend, indemnify, and hold Seller, its Affiliates, and all of their respective directors, officers, employees, agents, and independent contractors (“Indemnitees”) harmless from and against any and all damages, liabilities, injuries, losses, costs (including reasonable attorneys and experts fees at trial and on appeal), and expenses which may be incurred by, asserted against, or recoverable from any Indemnitee as a result of any actual or threatened action, suit or proceeding arising out of or relating in any way to the purchase of equipment from Seller.  The validity and interpretation of this Agreement and the enforcement thereof shall be governed by the laws of the State of California without regard to any principles governing conflicts of laws.  Any dispute arising from the purchase of equipment from Seller must be resolved in the State Courts of California.
    Images sell!
    Get Supersized Images & Free Image Hosting
    Attention Sellers - Get Templates
    Image Hosting, Scheduling at Auctiva.com.